Systems Testing

eclad meets the most severe performance categories of the Centre for Window and Cladding Technology (CWCT) and has been independently tested by Wintech Engineering Ltd a fully accredited test laboratory.

The eclad system has achieved ‘CE’ marking status as defined by Federation of European Window & Curtain Walling Manufacturers’ Association (FAECF) and is deemed to show compliance with all relevant standards throughout the European Union Member States including thermal and acoustic values.

Summary of Test Results

Test Peak Test Pressure Result &
Classification
Achieved
1 Air Leakage – Infiltration 600 Pa Pass (A4)
2 Air Leakage – Exfiltration 600 Pa no criteria¹
3 Water Penetration – Static 600 Pa Pass (R7)
4 Wind Resistance – Serviceability 2400 Pa Pass
5 Repeat Air Leakage – Infiltration² 600 Pa Pass
6 Repeat Air Leakage – Exfiltration² 600 Pa no criteria¹
7 Repeat Water Penetration – Static² 600 Pa Pass
8 Water Penetration – Dynamic Aero Engine 600 Pa Pass
9 Water Penetration – Dynamic Fan 300-900 Pa (cycle) Pass
10 Water Penetration – Hose n/a Pass
11 Wind Resistance – Safety 3600 Pa Pass
12 Impact – Safety (Soft Body) Internal – Pass (I 4)
External – Pass (E 1-3)³
13 Airborne Sound Insulation 44dBA (Rw + Ctr)
14 Thermal Transmittance 0.35 W/m2K
These results are valid only for the conditions under which the test was conducted
Note ¹:
There is no classification requirement for exfiltration testing in CWCT standard for systemised building envelopes – section 5.
Note ²:
Repeat Air Permeability and Water Penetration tests are passed as part of the Wind resistance – Serviceability test requirements.

Note ³:
Dependant on stone type

Results copied from Wintech Engineering Ltd. report PSR/R1761/06/1194/WEL

 

Contact Information

IRELAND
Grangegeeth,
Slane, Co. Meath, Ireland
C15 DD71
Tel: +353 1 890 2460
Email: info@eclad.ie

SPAIN
Parque Empresarial Porto do Molle,
Centro de Negocios, Of. 136,
36350 Nigrán, Spain
Tel: +34 986 120 941
Email: info@eclad.ie

UNITED KINGDOM
Tel: +353 1 890 2460
Email: info@eclad.ie

UNITED STATES
8906 S. Harlem Ave.
Bridgeview, IL 60455, USA
Tel: +1 (630) 595 6911
Email: info.usa@eclad.ie

Milestones

  • Hitting the Ground Running In Yorba Linda
  • Regis Cote residence in Quebec
  • Huddersfield University new Oastler Building
  • Eclad win 2015 MIA Pinnacle award
  • John Hancock Tower, Chicago. New Entrance Lobby Water Feature

Contact Us

IRELAND
T: +353 1 890 2460
E: info@eclad.ie

SPAIN
T: +34 986 120 941
E: info@eclad.ie

 

UK
T: +353 1 890 2460
E: info@eclad.ie

USA
T: +1 (630) 595 6911
E: info.usa@eclad.ie